JST-1KW hydrogen   generator

JST-1KW Specification

Rated power

20℃,101.3KPa the power is from 0 to 1000W

Rated current

The voltage is 54V,the current is from 0 to 17.5A

Rated voltage

54V

Output voltage

46 to 54V

Voltage range

±1V

Cell stack overall   dimension

352mm*380mm*430mm

Cabinet overall dimension

800mm*940mm*1760mm

Cell stack weight(not including attachment)

11kg

 

Cell stack weight( including attachment)

18kg

Total weight

253.5kg

Life expectancy

500hrs later10%   will be reduced,2000hrs   later 20% reduced.

Operating temp

0℃to 40℃ standard(Future standard will be from -10℃to 40℃)

Relative humidity

0 to 95%,Non-condensing

Communication

Rs485

Standby power   consumption

Less than 3% peak   power(DC)

Cooling type

Air (integrated   cooling fan)

H2 inlet pressure

0.55 to 0.65bar

H2 purity

More than 99.95%   dry H2

Consumption amount

Less than   0.78Nm3/kWh(Average max load)

Start-up time

At normal   temperature, less than 2 min

Cell stack’s   capacity

More than 35% peak   power

Max noise

At normal operation,   1.5 meter distance will be less than 70db.

Storage temp

-20℃ to 50℃

Emergency power’s   hours

6 to 8hrs

 

JST-2KW hydrogen   generator

JST-2KW Specification

Rated power

20℃,101.3KPa the power is from 0 to 2000W

Rated current

The voltage is 54V,the current is from 0 to 37A

Rated voltage

54V

Output voltage

46 to 54V

Voltage range

±1V

Cell stack overall   dimension

352mm*550mm*430mm

Cabinet overall dimension

850mm*1010mm*2000mm

Cell stack weight(not including attachment)

21kg

Cell stack weight( including attachment)

38kg

 

Total weight

349kg

Life expectancy

500hrs later10%   will be reduced,2000hrs   later 20% reduced.

Operating temp

0℃to 40℃ standard(Future standard will be from -10℃to 40℃)

Relative humidity

0 to 95%,Non-condensing

Communication

Rs485

Standby power   consumption

Less than 3% peak   power(DC)

Cooling type

Air (integrated   cooling fan)

H2 inlet pressure

0.55 to 0.65bar

H2 purity

More than 99.95%   dry H2

Consumption amount

Less than   0.78Nm3/kWh(Average max load)

Start-up time

At normal temperature,   less than 2 min

Cell stack’s   capacity

More than 35% peak   power

Max noise

At normal operation,   1.5 meter distance will be less than 70db.

Storage temp

-20℃ to 50℃

Emergency power’s   hours

6 to 8hrs

 

JST-3KW hydrogen   generator

JST-3KW Specification

Rated power

20℃,101.3KPa the power is from 0 to 3000W

Rated current

The voltage is 54V,the current is from 0 to 56A

Rated voltage

54V

Output voltage

46 to 54V

Voltage range

±1V

Cell stack overall   dimension

630mm*500mm*522mm

Cabinet overall dimension

1510mm*1165mm*1850mm

Cell stack weight(not including attachment)

32kg

Cell stack weight( including attachment)

52kg

 

Total weight

937kg

Life expectancy

500hrs later10%   will be reduced,2000hrs   later 20% reduced.

Operating temp

0℃to 40℃ standard(Future standard will be from -10℃to 40℃)

Relative humidity

0 to 95%,Non-condensing

Communication

Rs485

Standby power   consumption

Less than 3% peak   power(DC)

Cooling type

Air (integrated   cooling fan)

H2 inlet pressure

0.55 to 0.65bar

H2 purity

More than 99.95%   dry H2

Consumption amount

Less than   0.78Nm3/kWh(Average max load)

Start-up time

At normal   temperature, less than 2 min

Cell stack’s   capacity

More than 35% peak   power

Max noise

At normal operation,   1.5 meter distance will be less than 70db.

Storage temp

-20℃ to 50℃

Emergency power’s   hours

6 to 8hrs

 

JST-5KW hydrogen   generator

JST-5KW Specification

Rated power

20℃,101.3KPa the power is from 0 to 5000W

Rated current

The voltage is 54V,the current is from 0 to 93A

Rated voltage

54V

Output voltage

46 to 54V

Voltage range

±1V

Cell stack overall   dimension

630mm*500mm*522mm

Cabinet overall dimension

1510mm*1165mm*2044mm

Cell stack weight(not including attachment)

32kg

Cell stack weight( including attachment)

52kg

 

Total weight

1000kg

Life expectancy

500hrs later10%   will be reduced,2000hrs   later 20% reduced.

Operating temp

0℃to 40℃ standard(Future standard will be from -10℃to 40℃)

Relative humidity

0 to 95%,Non-condensing

Communication

Rs485

Standby power   consumption

Less than 3% peak   power(DC)

Cooling type

Air (integrated   cooling fan)

H2 inlet pressure

0.55 to 0.65bar

H2 purity

More than 99.95%   dry H2

Consumption amount

Less than   0.78Nm3/kWh(Average max load)

Start-up time

At normal   temperature, less than 2 min

Cell stack’s   capacity

More than 35% peak   power

Max noise

At normal operation,   1.5 meter distance will be less than 70db.

Storage temp

-20℃ to 50℃

Emergency power’s   hours

6 to 8hrs

 


http://www.jspower-hydrogen.com/